Skip to Main Content

PW196AR - Dual Output Argon Flowmeter Regulator CGA 580

Packaging: 1of1
$281.16/ea $187.44/1of1 only $187.44/eaSave 33%

In stock

SKU: 196AR-60-580 Categories: ,

OVERVIEW

Precision Gas Control for Advanced Welding Applications

The Dual Flowmeter Regulator CGA580 is an essential tool for professional fabricators and pipe welders who demand precision and efficiency. Designed to streamline gas management, this unit features two independent flow tubes mounted to a single regulator body. This configuration allows you to draw shielding gas for your welding torch and a secondary line for back-purging from a single cylinder, eliminating the need for expensive Y-valves or cumbersome secondary tanks.

Constructed with a robust brass body, this regulator is built to withstand the rigors of daily industrial use. The CGA 580 inlet connection ensures compatibility with standard high-pressure cylinders containing Argon, Helium, or Argon/CO2 blends. Each flow tube is calibrated for 0-60 SCFH (Standard Cubic Feet per Hour), providing granular control over gas flow rates. This is particularly critical in sanitary stainless steel welding, where a precise purge flow is necessary to prevent oxidation (sugaring) on the root pass without wasting expensive gas.

The flowmeters utilize a ball-float design within a durable polycarbonate tube, offering clear visibility of flow settings even from a distance. The pressure regulation mechanism ensures a steady output pressure, smoothing out fluctuations from the cylinder as it empties. Whether you are setting up a complex TIG welding station or simply need to run two MIG machines from a central gas source, this dual flowmeter offers the versatility and reliability required for high-quality fabrication.

Key Technical Benefits

Unlike standard gauge regulators which measure pressure, this flowmeter measures dynamic flow, providing a more accurate reading of gas consumption. The dual-outlet design is engineered to maintain flow accuracy even when both lines are active, ensuring that your weld pool and purge chamber receive consistent coverage. The unit also includes a safety pressure relief valve and standard 5/8"-18 RH outlet fittings for universal hose compatibility.

Additional Information
Packaging Description:1of1
Item:Flowmeter
Brand:Generic
Used On Which Gas:argon-or-weldmix
CGA Fitting:cga580
Max Inlet:NA
Max Outlet:60ft3-hr
Gas Type:Argon, Argon/CO2 Mix, Helium
Flow Range:0-60 SCFH
Inlet Connection:CGA 580
Outlet Connection:5/8"-18 RH Female
Material:Brass Body, Polycarbonate Tube
Design Type:Dual Flow Tube, Piston Style Mechanism
----- new values below ----
Gas Type:Argon, Argon/CO2 Mix, Helium
Flow Range:0-60 SCFH
Inlet Connection:CGA 580
Outlet Connection:5/8"-18 RH Female
Material:Brass Body, Polycarbonate Tube
Design Type:Piston Style Mechanism, Dual Flow Tube
brand:generic
cga-fitting:cga580
item:flowmeter
used-on-which-gas:argon-or-weldmix
max-outlet:60ft3-hr

INCLUDED

  • 1 x Dual Flowmeter Regulator Assembly
  • 2 x Flow Tubes (0-60 SCFH)
  • 1 x CGA 580 Inlet Stem
  • 2 x 5/8"-18 RH Outlet Fittings

APPLICATIONS

  • TIG Welding (GTAW): Essential for back-purging stainless steel and titanium piping or vessels.
  • Dual Station Setup: Supply shielding gas to two separate welding machines from a single cylinder.
  • MIG Welding (GMAW): Suitable for aluminum MIG setups requiring Argon.
  • Laboratory & Industrial: Precise gas distribution for non-welding applications requiring inert gas flow.

FAQ

A dual flowmeter allows you to run two separate gas lines from a single cylinder, each with its own independent flow rate control. This is most commonly used for TIG welding where one line supplies the torch and the other supplies the back-purge for the weld root.

The CGA 580 fitting is the standard connection for inert gases including pure Argon, Nitrogen, and Helium. It is also used for many Argon/CO2 welding mixes, though some high-CO2 mixes use CGA 320.

Not directly. Pure CO2 cylinders typically use a CGA 320 fitting which requires a washer. This regulator has a CGA 580 fitting. You would need an adapter to use it on a CO2 tank, but it is primarily designed for Argon-based gases.

Each tube is calibrated to measure flow from 0 to 60 SCFH (Standard Cubic Feet per Hour).

For most standard ball-type flowmeters, the flow rate is read at the center of the ball when it is floating in the tube. Align the center of the ball with the desired line on the scale.

Yes, it is a combination regulator and flowmeter. It steps down the high pressure from the cylinder (up to 3000 PSI) to a usable working pressure, and then the flowmeters control the volume of gas released.

Yes, the flow control knobs allow you to completely close off flow to either tube, so you can use it as a single flowmeter when the second line is not needed.

The outlets are standard 5/8"-18 RH (Right Hand) female fittings, which accept the standard 'B-size' inert gas hose nuts found on most American welding equipment.