Skip to Main Content

222-0009 - Miller Smith Silverline 220 Series High Purity Two-Stage Regulator, CGA 580

Packaging: 1 per ea
string(11) "testing exp" string(0) ""
$912.30/ea $603.89/1 per ea only $603.89/eaSave 34%

Usually ships within 3-5 business days

string(11) "testing exp" string(0) ""
SKU: MIL222-0009 Categories: ,

OVERVIEW

Precision Control for Analytical Applications

The Miller Smith 222-00-09 Silverline High Purity Analytical Two Stage Regulator is engineered to meet the rigorous demands of laboratory and analytical environments. Designed specifically for high purity, non-corrosive gases, this regulator is a critical component for applications requiring absolute stability and cleanliness, such as gas chromatography (thermal conductivity, flame ionization, flame photometry, and electron capture). The 220 Silverline Series represents the pinnacle of Miller Smith's regulator technology, combining rugged construction with sensitive control mechanisms.

Advanced Two-Stage Architecture

One of the defining features of the 222-00-09 is its two-stage design. Unlike single-stage regulators that allow delivery pressure to rise as the cylinder pressure falls (the decaying inlet characteristic), this two-stage unit maintains a constant delivery pressure throughout the entire life of the cylinder. This is essential for analytical instruments where even minor fluctuations in carrier gas pressure can skew results or disrupt calibration. By stepping down the pressure in two stages, the regulator isolates the final delivery pressure from the variables of the supply cylinder.

Material Integrity and Purity

To ensure the integrity of the gas stream, this regulator features a stainless steel diaphragm. Unlike elastomeric diaphragms that can off-gas or absorb contaminants, stainless steel provides a non-reactive barrier that preserves the purity of the gas. This is complemented by a filtered seat that prevents particulate contamination, extending the service life of the seat and ensuring consistent performance. The body, bonnet, and gauges are plated to provide superior protection against environmental corrosion and to maintain a clean, professional appearance suitable for laboratory settings.

Safety and Versatility

Safety is paramount in high-pressure gas handling. The Miller Smith 222-00-09 includes a built-in capturable preset safety relief valve, which protects the regulator components and downstream equipment from over-pressurization. The unit is also designed to withstand vacuums generated during purging operations, making it highly versatile for complex gas management systems. With a CGA 580 inlet, it is compatible with standard inert gas cylinders (Nitrogen, Argon, Helium) and delivers a precise pressure range of 0-100 PSI via a 1/4" FNPT outlet connection.

Additional Information
Packaging Description:1 Per Ea
CGA Fitting:cga580
Item:Regulator
Max Inlet:3500psi
Max Outlet:100psi
Used On Which Gas:Argon or Nitrogen, Inert Gases
Series:220 Silverline
Diaphragm Material:Stainless Steel
Body Material:Plated Brass Bar Stock
Application:Gas Chromatography, High Purity Analytical
Outlet Connection:1/4" FNPT
----- new values below ----
Series:220 Silverline
Stages:Two Stage
Diaphragm Material:Stainless Steel
Body Material:Plated Brass Bar Stock
Application:High Purity Analytical, Gas Chromatography
Outlet Connection:1/4" FNPT
Brand:Miller Smith
CGA Fitting:cga580
Item:Regulator
Max Inlet:3500psi
Max Outlet:100psi
Used On Which Gas:Inert Gases, Argon or Nitrogen

INCLUDED

  • Miller Smith 222-00-09 Two-Stage Regulator
  • Instruction Manual

APPLICATIONS

  • Gas Chromatography (GC)
  • Thermal Conductivity Detectors
  • Flame Ionization Detectors
  • Flame Photometry
  • Electron Capture Detectors
  • Calibration Gas Mixtures
  • Carrier Gas Control
  • High Purity Inert Gas Delivery

FAQ

A two-stage regulator reduces the cylinder pressure in two steps, which allows it to maintain a constant delivery pressure even as the cylinder pressure drops. This eliminates the need for frequent readjustment and ensures stable flow for sensitive analytical instruments.

The CGA 580 fitting is the standard connection for inert gases. This includes Argon, Nitrogen, and Helium. It is also used for certain inert gas mixtures.

Stainless steel diaphragms are used in high-purity applications because they do not absorb or release contaminants (off-gassing) like rubber or neoprene diaphragms might. They also provide more precise pressure control.

The Miller Smith 222-00-09 is rated for a maximum inlet pressure of 3500 PSI, making it compatible with high-pressure cylinders.

Yes, the design allows it to withstand vacuums generated during purging operations, which is a common procedure in high-purity gas systems to remove contaminants before use.

This regulator features a 1/4" FNPT (Female National Pipe Thread) outlet connection, allowing for easy adaptation to various tube fittings or piping systems.

No, this regulator is recommended for high purity, non-corrosive pure gases and mixtures. It has a brass body which is not suitable for corrosive service.