OVERVIEW

Precision Control for Analytical Applications

The Miller Smith 223-01-08 Silverline High Purity Analytical Two Stage Regulator is engineered to meet the rigorous demands of laboratory and analytical environments. Designed specifically for applications requiring absolute gas purity and unwavering pressure stability, this regulator is a critical component for gas chromatography, flame ionization, and thermal conductivity workflows. The Silverline 220 Series distinguishes itself with a construction that prioritizes both precision and cleanliness, ensuring that your carrier gases and calibration mixtures are delivered without contamination or fluctuation.

Advanced Two-Stage Design

In analytical settings, pressure stability is paramount. The 223-01-08 utilizes a sophisticated two-stage design that reduces cylinder pressure in two steps. This mechanism ensures that the delivery pressure remains constant throughout the entire life of the cylinder, from full to nearly empty. Unlike single-stage regulators that may experience a "decaying" outlet pressure as the inlet pressure drops, this Miller Smith regulator maintains a steady flow, eliminating the need for constant manual adjustments and ensuring the integrity of sensitive analytical results.

Superior Materials and Construction

To maintain high purity standards, the regulator features a stainless steel diaphragm. Unlike elastomeric diaphragms that can outgas or absorb contaminants, stainless steel provides a non-reactive barrier that preserves the chemical composition of the gas stream. The body, bonnet, and gauges are plated to resist corrosion and maintain a clean exterior suitable for laboratory environments. Furthermore, the seat is filtered to prevent particulate contamination, which not only protects the integrity of the gas stream but also significantly extends the service life of the regulator seat itself.

Safety and Versatility

Safety is integrated into the design with a built-in capturable preset safety relief valve, protecting downstream equipment from over-pressurization. The regulator is also robust enough to withstand vacuums generated during purging operations, a common procedure in high-purity gas handling. With a CGA 540 inlet, it is compatible with standard oxygen and compatible high-purity gas cylinders, delivering a pressure range of 0-150 PSIG suitable for a wide array of analytical instruments.

Additional Information
Packaging Description:1 Per Ea
Gas Type:High Purity Gas, Oxygen
Stage Type:Two Stage
Inlet Connection:CGA-540
Outlet Connection:1/4" FNPT
Delivery Pressure Range:0-150 PSIG
Series:Silverline 220
Diaphragm Material:Stainless Steel
Body Material:Plated Brass Bar Stock
Application:Analytical, Gas Chromatography, High Purity Delivery
----- new values below ----
Series:Silverline 220
Diaphragm Material:Stainless Steel
Body Material:Plated Brass Bar Stock
Gauge Size:2-1/2 Inch
Application:Analytical, Gas Chromatography, High Purity Delivery
Brand:Miller Smith
Gas Type:Oxygen, High Purity Gas
Stage Type:Two Stage
Inlet Connection:CGA 540
Outlet Connection:1/4" FNPT
Delivery Pressure Range:0-150 PSIG
Max Inlet Pressure:3500 PSIG

INCLUDED

  • Miller Smith 223-01-08 Silverline Two Stage Regulator
  • Owner's Manual
  • Warranty Information

APPLICATIONS

  • Gas Chromatography (GC)
  • Flame Ionization Detectors (FID)
  • Thermal Conductivity Detectors (TCD)
  • Electron Capture Detectors (ECD)
  • Calibration Gas Mixtures
  • High Purity Carrier Gas Control
  • Research and Laboratory Applications
  • Emission Monitoring Systems

FAQ

A two-stage regulator reduces cylinder pressure in two steps, providing a constant delivery pressure regardless of fluctuations in the cylinder pressure. This eliminates the need for frequent readjustment as the cylinder empties.

The Miller Smith 223-01-08 is rated for a maximum inlet pressure of 3500 PSIG.

This regulator is equipped with a CGA 540 inlet connection, which is the standard standard for Oxygen and certain other high-purity gas mixtures depending on the cylinder valve.

A stainless steel diaphragm is non-reactive and does not absorb or outgas contaminants like rubber diaphragms might. This ensures the purity of the gas stream is maintained for analytical applications.

No, the Silverline 220 series is recommended for high purity, non-corrosive pure gases and mixtures. It is not designed for corrosive service.

The regulator features a 1/4" FNPT (Female National Pipe Thread) outlet connection.

Yes, the design allows the regulator to withstand vacuums generated during purging operations without damaging the internal components.

This model is calibrated for a delivery pressure range of 0-150 PSIG.