Skip to Main Content

252-8208 - Miller Smith 250 Silverline High Purity Oxygen Regulator, CGA 540, 0-100 PSI

Packaging: 1 per ea
string(11) "testing exp" string(0) ""
$572.09/ea $378.69/1 per ea only $378.69/eaSave 34%

Usually ships within 3-5 business days

string(11) "testing exp" string(0) ""
SKU: MIL252-8208 Categories: ,

OVERVIEW

Precision Control for High Purity Applications

The Miller Smith 252-82-08 Silverline High Purity Analytical Liquid Cylinder Regulator is a premium solution designed for the rigorous demands of laboratory and analytical environments. When dealing with high-purity gases, maintaining the integrity of the gas stream is paramount. This regulator addresses that need with a fully nickel-plated brass body, bonnet, and gauges. The nickel plating serves a dual purpose: it provides an aesthetically clean finish suitable for lab environments and, more importantly, offers superior corrosion resistance compared to standard brass, ensuring that the regulator itself does not introduce contaminants into your gas flow.

Engineered for Liquid Cylinders

Unlike standard industrial regulators, the 250 Silverline series is specifically engineered for use on liquid cylinders (dewars). It features a back-mount inlet connection, which positions the regulator correctly when attached to the liquid cylinder's gas use valve. This ergonomic design consideration simplifies installation and ensures the gauges are easy to read. Speaking of gauges, this model is equipped with large 2-1/2 inch single-scale gauges. These oversized dials make it incredibly easy for technicians to monitor cylinder volume and delivery pressure from a distance, enhancing safety and efficiency in busy laboratory settings.

Cryogenic Reliability

One of the critical challenges in regulating gas from liquid sources is the potential for cold temperatures to affect internal components. The Miller Smith 252-82-08 utilizes a large 1-7/8 inch stainless steel diaphragm. Stainless steel is the material of choice for cryogenic applications because it retains its flexibility and strength even when exposed to the lower temperatures often associated with high-withdrawal rates from liquid cylinders. This ensures precise pressure control and a long service life, preventing the drift and failure common in lesser regulators.

Exclusive Sure-Seat™ Technology

At the heart of this regulator is Smith’s exclusive Sure-Seat™ filtered seat technology. This innovative design incorporates a filter directly into the high-pressure seat assembly, preventing microscopic particles and contamination from entering the seating area. Debris is the number one cause of regulator failure and creep; by blocking it effectively, the Sure-Seat™ significantly reduces repair costs and downtime. With a delivery range of 0-100 PSIG and a CGA 540 connection for oxygen service, this regulator is the dependable choice for analytical work requiring stable, clean gas delivery.

Additional Information
Packaging Description:1 Per Ea
CGA Fitting:cga540
Item:Regulator
Max Inlet:3500psi
Max Outlet:100psi
Used On Which Gas:Oxygen
Gas Type:Oxygen
Connection Type (CGA):CGA 540
Inlet/Outlet Pressure:Delivery: 0-100 PSIG, Max Inlet: 3500 PSIG
Body Material:Nickel-Plated Brass
Diaphragm Material:Stainless Steel
Gauge Type:2-1/2 in Single Scale
Orientation:Back Mount
Series:250 Silverline
Applications:High Purity Gas Handling, Laboratories, Liquid Cylinders
----- new values below ----
Gas Type:Oxygen
Connection Type (CGA):CGA 540
Inlet/Outlet Pressure:Max Inlet 3500 PSIG, Delivery 0-100 PSIG
Body Material:Nickel Plated Brass
Diaphragm Material:Stainless Steel
Gauge Type:2-1/2 in. Single Scale
Orientation:Back Mount
Series:250 Silverline
Applications:High Purity Gas Handling, Liquid Cylinders, Laboratories
Brand:Miller Smith
CGA Fitting:cga540
Item:regulator
Max Inlet:3500psi
Max Outlet:100psi
Used On Which Gas:oxygen

INCLUDED

  • 1 x Miller Smith 252-82-08 Silverline Regulator
  • 1 x Set of Instructions

APPLICATIONS

  • High Purity Gas Handling
  • Bulk Gas Distribution
  • Liquid Cylinder Gas Delivery
  • Analytical Laboratories
  • Research Facilities
  • Laser Cutting Assist Gas Supply

FAQ

The Miller Smith 252-82-08 is rated for a maximum inlet pressure of 3500 PSIG.

This regulator is designed to control the delivery of gas, not liquid. It connects to the gas use valve of a liquid cylinder (dewar) to regulate the vaporized gas pressure.

The CGA 540 connection is the standard standard for Oxygen service in the United States.

A stainless steel diaphragm is used because it provides superior performance in cryogenic applications. It withstands the cold temperatures associated with liquid cylinders better than elastomers and ensures high purity by not off-gassing.

This regulator has a delivery pressure range of 0-100 PSIG.

The nickel plating on the body, bonnet, and gauges protects the regulator from corrosion, extends its service life, and helps maintain the purity of the environment by preventing brass oxidation.

While the CGA 540 fitting will physically connect to a standard oxygen cylinder, the regulator is 'back mount' (rear entry) designed specifically for the geometry of liquid cylinders. Using it on a standard cylinder may result in the gauges facing an awkward direction.

Sure-Seat is a filtered seat design exclusive to Smith Equipment. It prevents contamination from entering the seating area, which is the leading cause of regulator creep and failure.