Skip to Main Content

S-25-M - Syner-G M-25 Station Regulator for Pipeline Systems

Packaging: 1 of each
$499.20/ea $348.16/1 of each only $348.16/eaSave 30%

Usually ships within 3-5 business days

OVERVIEW

Precision Pipeline Control with Syner-G

The Syner-G Model M-25 Secondary Single Stage Regulator (SKU: S-25-M) is an essential component for industrial facilities utilizing bulk gas systems or manifold distribution networks. Unlike primary regulators that mount directly to high-pressure cylinders, this secondary "station" regulator is engineered to manage the intermediate pressures found in shop pipelines, stepping them down to the precise working pressures required for welding, cutting, and brazing operations.

Constructed with industrial-grade materials, the M-25 series focuses on reliability and longevity. In a centralized gas system, pressure fluctuations can occur as multiple users draw from the line simultaneously. The Syner-G M-25 acts as a local stabilizer, isolating the specific workstation from these systemic variances. This ensures that the flow rate remains constant, which is critical for maintaining weld integrity and process consistency. The single-stage design is optimized for the lower inlet pressures typical of pipeline drops (usually under 200 PSI), providing a responsive and accurate adjustment mechanism.

Safety is paramount in gas distribution. The Syner-G M-25 includes standard safety features designed to prevent over-pressurization at the torch or machine. Its compact footprint allows for easy installation on wall brackets or station drops without cluttering the workspace. Whether you are outfitting a new training facility, a large fabrication plant, or simply upgrading a single station, the S-25-M offers the performance characteristics demanded by professional gas management protocols.

Key Technical Benefits:

  • Stable Output: Mitigates line pressure spikes to protect sensitive downstream equipment.
  • Durable Build: Brass body construction resists corrosion and mechanical damage in harsh shop environments.
  • Cost-Effective: Provides high-end performance at a value point suitable for equipping multiple stations.
Additional Information
Packaging Description:1 of each, 1 per each
Item:Regulator
Brand:n/a
Used On Which Gas:n/a
CGA Fitting:n/a
Max Inlet:200psi, 250psi
Max Outlet:n/a
Series:M-25
Applications:Manifold Systems, Pipeline Distribution
----- new values below ----
Regulator Type:Station Regulator, Secondary Regulator
Stage:Single Stage
Series:M-25
Applications:Pipeline Distribution, Manifold Systems
brand:Syner-G
item:Regulator
max-inlet:200psi
packaging-description:1 per each

INCLUDED

  • 1 x Syner-G Model M-25 Secondary Single Stage Regulator
  • 1 x Instruction Manual

APPLICATIONS

  • Industrial Fabrication Shops with Manifold Systems
  • Welding Training Facilities and Schools
  • Automotive Manufacturing Plants
  • Shipyards and Heavy Equipment Repair
  • Laboratory Gas Distribution

FAQ

A primary regulator attaches directly to a high-pressure cylinder (up to 3000+ PSI) to reduce it to an intermediate pressure. A secondary regulator, like the Syner-G M-25, is installed on a pipeline or manifold station to take that intermediate pressure (typically <200 PSI) and reduce it further to the precise working pressure needed for the torch or machine.

No. This is a station regulator designed for pipeline drops with lower inlet pressures. It is not rated for the high pressure found in standard gas cylinders. Connecting it directly to a high-pressure tank could result in equipment failure and serious safety hazards.

The Model M-25 is generally compatible with common non-corrosive industrial gases. However, you must ensure that the specific fittings and internal seals of the S-25-M unit you have are rated for your specific gas (e.g., Inert vs. Oxygen vs. Fuel). Always check the label and manual for specific gas compatibility.

Station regulators typically come with one gauge to show the delivery pressure, as the inlet pressure is determined by the pipeline system. However, configurations can vary, so please verify the specific product image or contents list.

The regulator should be threaded into the station drop valve on your pipeline system. Ensure the threads match (typically CGA or NPT standards) and use an appropriate sealant or tape if required by the thread type (never use oil or grease on oxygen equipment). Leak test all connections before use.

If you are not using a station regulator like the M-25, line pressure fluctuations from other users can affect your flow. Installing this regulator isolates your station and provides a steady flow. If you already have one and flow is fluctuating, check for debris in the seat or a damaged diaphragm.

As a secondary regulator, the maximum inlet pressure is typically rated around 200 PSI to 400 PSI, depending on the specific sub-model. It is crucial never to exceed the rated inlet pressure marked on the device.

Syner-G is known for providing cost-effective, industrial-quality welding accessories and gas equipment that meet standard performance requirements for fabrication and manufacturing environments.