Skip to Main Content
Canadian
Canadian owned and operated

WWWBG-2400-b - 2-Inch Acetylene Cylinder Pressure Gauge, 0-400 PSI Inlet

Packaging: 1 per each
$20.02/ea

In stock

SKU: PG2-400 Categories: ,

OVERVIEW

Precision Monitoring for Acetylene Systems

In the realm of industrial gas management, accuracy and safety are paramount. The 2-Inch Acetylene Pressure Gauge (0-400 PSI) is engineered to provide reliable monitoring of cylinder contents for professional welding and cutting setups. Designed specifically for the unique properties of acetylene gas, this gauge features internal materials compatible with the gas to prevent corrosion and ensure long-term stability. The 0-400 PSI scale is perfectly calibrated for acetylene cylinders, which typically hold pressure around 250 PSI at full capacity, giving the operator a clear and immediate visual indication of the remaining gas supply without the clutter of unnecessary high-pressure markings found on universal gauges.

The gauge features a standard 2-inch dial face, which strikes the perfect balance between compactness for regulator mounting and readability for the operator. The high-contrast numerals and needle allow for quick checks from a distance, ensuring that workflow is not interrupted by the need to squint at small dials. The connection is a standard 1/4-inch NPT bottom mount, the industry standard for the majority of industrial gas regulators, making this an essential component for maintenance and assembly of gas control equipment.

Safety and Compliance

Using the correct gauge for the specific gas service is a critical safety rule in welding. This gauge is explicitly marked for Acetylene use, ensuring that it is not accidentally installed on high-pressure oxygen systems where oil or incompatibility could pose severe risks. The robust case design protects the sensitive internal mechanism from the inevitable bumps and knocks of the industrial environment, while the clear lens ensures the face remains legible even after prolonged use in dusty shop conditions. Whether you are outfitting a new manifold system or maintaining a fleet of portable oxy-fuel outfits, this gauge delivers the precision required for safe operation.

Technical Reliability

The internal bourdon tube mechanism is crafted to withstand the pressure fluctuations inherent in opening and closing cylinder valves. By providing a steady reading of the inlet pressure, this gauge helps operators plan their gas usage effectively, reducing waste and preventing the dangerous practice of drawing acetylene down below recommended residual pressures. It is an indispensable tool for any facility prioritizing safety and efficiency in their oxy-fuel operations.

Additional Information
Gas Service:Acetylene
Pressure Range:0-400 PSIG
Dial Size:2 Inch
Mount Type:Bottom Mount
Thread Size:1/4" NPT
Application:Cylinder Content Measurement, Regulator Replacement Part
----- new values below ----
Gas Service:Acetylene
Pressure Range:0-400 PSIG
Dial Size:2 Inch
Mount Type:Bottom Mount
Thread Size:1/4" NPT
Application:Cylinder Content Measurement, Regulator Replacement Part
Diameter (in):2"
Max Psi:400psi
Used On Which Gas:Acetylene
Used on a:Regulator
Which Side?:Contents

INCLUDED

  • 1 x 2-Inch Acetylene Pressure Gauge (0-400 PSI)

APPLICATIONS

  • Monitoring acetylene cylinder pressure on oxy-fuel regulators
  • Replacement of broken or illegible inlet gauges
  • Industrial gas manifold systems
  • Portable welding and cutting outfits
  • HVAC purging and brazing equipment

FAQ

This is an inlet gauge designed to measure the tank (cylinder) pressure. It has a range of 0-400 PSI, which covers the standard pressure of a full acetylene cylinder.

Most likely, yes. This gauge has a standard 1/4" NPT bottom mount thread, which is used by the vast majority of regulator manufacturers including Victor, Harris, and Smith for their 2-inch gauges.

No. This gauge is specifically designed and labeled for Acetylene. Oxygen gauges require different internal cleaning standards to prevent combustion, and Argon cylinders have much higher pressures (up to 3000+ PSI) which would burst this gauge.

You should use a small amount of PTFE thread seal tape or a suitable pipe thread sealant. Ensure the tape or sealant is rated for gas service and do not over-apply, as you don't want debris entering the regulator body.

Gauges are typically selected so that the normal operating pressure falls within the middle third of the scale for best accuracy and safety. Since Acetylene cylinders are roughly 250 PSI, a 400 PSI scale provides adequate headroom.

These gauges typically feature a durable polycarbonate or plastic lens to resist shattering if dropped, which is a common hazard in welding environments.

The gauge face is 2 inches in diameter, which is the standard size for most industrial gas regulators.

Inlet gauges for cylinder content usually do not have a red line warning at 15 PSI. That is typically found on the working pressure (outlet) gauge. This gauge shows the total tank pressure.